Specifications Table for ATXM-N / ARXM-R

ATXM25N2V1B / ARXM25R5V1B ATXM35N2V1B / ARXM35R5V1B
Cooling capacity Min. kW 1.30 1.40
  Nom. kW 2.50 3.40
  Max. kW 3.20 4.00
Heating capacity Min. kW 1.30 1.40
  Nom. kW 2.80 4.00
  Max. kW 4.70 5.20
Nominal efficiency Annual energy consumption kWh 285 416
  COP   5.00 4.04
  EER   4.39 4.09
  Energy labeling Directive Cooling   A A
    Heating   A A
Space cooling Annual energy consumption kWh/a 102 139
  Energy efficiency class   A+++ A+++
  Capacity Pdesign kW 2.50 3.40
  SEER   8.55 8.55
Space heating (Average climate) Annual energy consumption kWh/a 659 687
  Capacity Pdesign kW 2.40 2.50
  Energy efficiency class   A+++ A+++
  SCOP/A   5.10 5.10
Notes (1) - See separate drawing for operation range (1) - See separate drawing for operation range
  (2) - See separate drawing for electrical data (2) - See separate drawing for electrical data
  (3) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (3) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.
  (4) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (4) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.